From Study XX · Part 2 of 3, Exhibit 13
Most of a credited removal is water that never left the cell
Source. Derived from Virginia DEQ, Stormwater Design Specification No. 9 (2011, 2013).
Method. Total removal = 1 − (1 − RR) × (1 − T), where RR is the runoff-reduction credit and T the treatment credit on outflow. The runoff-reduction share is RR itself; the treatment share is (1 − RR) × T. Modeled design credits, not measurements.
| Design and pollutant | From runoff reduction (points) | From treatment of outflow (points) | Total credited removal (%) |
|---|---|---|---|
| Level 1, phosphorus | 40 | 15 | 55 |
| Level 1, nitrogen | 40 | 24 | 64 |
| Level 2, phosphorus | 80 | 10 | 90 |
| Level 2, nitrogen | 80 | 12 | 92 |