From Study XXXII, Exhibit 6

In measured trials, runoff from asphalt started about 9.5 degrees Celsius warmer than runoff from sod

StudySettingKindMeasure°CNote
Thompson et al. 2008, as summarized by EPA CADDISAsphalt and sod plots, 24 rainfall simulations, WisconsinmeasuredAsphalt surface minus sod surface before rain20more than
Thompson et al. 2008, as summarized by EPA CADDISAsphalt and sod plots, 24 rainfall simulations, WisconsinmeasuredInitial asphalt runoff temperature35
Thompson et al. 2008, as summarized by EPA CADDISAsphalt and sod plots, 24 rainfall simulations, WisconsinmeasuredInitial sod runoff temperature25.5
Thompson et al. 2008, as summarized by EPA CADDISAsphalt and sod plots, 24 rainfall simulations, WisconsinmeasuredInitial asphalt runoff minus initial sod runoff9.5calculated from the two values above
Thompson et al. 2008, as summarized by EPA CADDISAsphalt and sod plots, 24 rainfall simulations, WisconsinmeasuredAverage drop in asphalt runoff temperature over a 1-hour simulation4.1
Herb et al. 2009, Journal of the American Water Resources AssociationUnshaded pond below an asphalt lot, six years of observed rainfallsimulatedAverage pond outflow temperature minus inflow temperature1.2

Source. U.S. EPA, CADDIS Volume 2, “Urbanization: Temperature” (summarizing Thompson et al. 2008); Herb, Mohseni and Stefan, “Simulation of Temperature Mitigation by a Stormwater Detention Pond,” Journal of the American Water Resources Association (2009).

Download CSV. Data and chart licensed CC BY 4.0.